Description
Replacement Atom line-marking pump using the Shurflo 8000-941-280 model. Used in the Atom ready-to-use paint setup and suitable low-volume marking systems. Match the full pump model and machine connections before ordering.
Shurflo 8000-941-280 specifications
| Pump model | Shurflo 8000-941-280 |
|---|---|
| Power supply | 12V DC |
| Pump design | 8000 Series diaphragm pump with internal bypass |
| Maximum pressure rating | 80 psi / approximately 5.5 bar |
| Maximum flow rating | 1.2 US gallons/min / approximately 4.5 L/min |
| Pump port connection | 3/8-inch NPT female |
These are pump ratings, not the paint output through a marking nozzle. Maximum flow and maximum pressure are separate ratings and do not describe one operating point. Check the fitted pump label, connections and machine requirements.
Ready-to-use paint and nozzle choice
Turfmate uses this pump in the Atom low-volume setup for ready-to-use grass marking paint. Compare our Gold metal, White and Blue hollow-cone nozzles and Atomic ready-to-use paint.
The hollow-cone guide lists nozzle output at 4 bar. The pump’s 80 psi rating does not mean the nozzle automatically runs at 4 bar. Confirm the working pressure and measure actual paint flow on the complete machine.
Estimate linear metres by nozzle colour and travel speed →
Why does this pump use a bypass?
An internal bypass supports applications that need pressure with a low outlet flow. It differs from an automatic demand-switch arrangement. Follow the machine’s controls and the pump instructions; do not assume closing the nozzle switches the motor off.
Will it fit my existing line marker?
Check the complete model code, 12V supply, wiring connector, mounting plate, inlet and outlet fittings, and the machine’s pressure requirements. Another Shurflo 8000 Series pump is not necessarily an interchangeable replacement. For a different machine, send us its make, model and a photo of the existing pump label and connections.
What should I check if paint flow is low?
Before inspecting the system, disconnect power and release pressure according to the machine instructions. Check the paint supply, inlet filter, hoses and nozzle for restrictions, and check the power supply against the pump label. Use the paint maker’s cleaning directions and confirm cleaner compatibility with the pump materials.
Installation and technical information
Use the machine instructions and the Shurflo 8000 Series installation and operation manual (PDF). This is a series manual; the exact model label takes precedence for model-specific ratings. Confirm the correct wiring and circuit protection for your installation.
Ask Turfmate to check the replacement fit →
Shop line marking machine parts → · Compare grass and synthetic marking paints →